top of page
server-parts.eu

server-parts.eu Blog

Dell PowerEdge R760 NVMe SSD Upgrade Options and Compatibility

  • Writer: server-parts.eu server-parts.eu
    server-parts.eu server-parts.eu
  • Apr 28
  • 20 min read

Updated: Apr 29

The Dell PowerEdge R760 is a high-performance 16th Generation (2U) rack server built to handle demanding workloads. One of the most impactful upgrades for this server is installing PCIe Gen4 NVMe SSDs to supercharge storage performance.


Dell PowerEdge R760 NVMe SSDs - Save Up to 80%

✔️ No Upfront Payment Required - Test First, Pay Later!


In this article, we’ll explore Dell R760 NVMe SSD upgrade options, compatibility considerations, and best practices - we’ll focus exclusively on Gen4 NVMe drives.


Dell PowerEdge R760 server with PCIe Gen4 NVMe SSD upgrade installed, showcasing enterprise-grade U.2 and U.3 form factor NVMe SSDs in hot-swap drive bays for high-performance storage solutions, maximizing IOPS, throughput, and low latency for virtualization, databases, AI workloads, and cloud infrastructure, demonstrating Dell R760 NVMe upgrade options and enterprise server storage best practices. Server-parts.eu.


NVMe SSD Drive Bay Configurations on the Dell PowerEdge R760


Dell offers multiple chassis configurations for the PowerEdge R760, giving flexibility in how many NVMe drives you can install. The R760’s backplane is NVMe-capable, meaning it can directly connect high-speed NVMe drives to the server’s PCIe bus for maximum performance. Key points about Dell R760 NVMe compatibility include:


  • 🔹 Front Bay Options: Depending on the chassis, the R760 supports 8, 16, or 24 front 2.5-inch drive bays. All these bays can be configured for NVMe SSDs if you have the appropriate NVMe backplane and controllers​. For example, an R760 can be ordered with an 8-bay NVMe backplane, a 16-bay, or even a full 24-bay NVMe configuration for maximum flash storage capacity.​ In its highest configuration, up to 24 NVMe SSDs can be installed in the front, enabling huge storage potential (Dell quotes up to ~368 TB with 24 NVMe drives at 15.36 TB each)​.



  • 🔹 Rear Bay Options: Some R760 configurations offer rear drive bays for additional drives. You might have 2 or 4 extra 2.5-inch slots in the back that also support NVMe (as well as SAS/SATA)​. These are often used for boot drives or extra storage where needed. For instance, an R760 can have 24 NVMe in front plus 2 NVMe in the rear (depending on config) for even more capacity. Keep in mind that using rear bays may require specific riser cards or cabling.



  • 🔹 PCIe Gen4 Support: The R760’s platform natively supports PCIe 4.0, so any NVMe drive you install in the hot-swap bays will run at Gen4 speeds (assuming the drive itself is Gen4). This doubles the bandwidth compared to older Gen3 servers. Each NVMe drive bay typically provides a x4 PCIe Gen4 link, allowing up to ~8 GB/s throughput per drive in ideal conditions. The backplane and cabling in the R760 are designed to handle these high speeds.



  • 🔹 U.3 Backplane (U.2 Drive Support): The R760 uses the U.3 connector for its 2.5" drive bays. U.3 is a universal backplane interface that supports NVMe, SAS, or SATA drives in the same slot. For NVMe upgrades, this means the server’s drive bays can accept standard U.2 form factor NVMe SSDs (which have the same SFF-8639 connector; U.3 is backward-compatible with U.2). In practical terms, you can use common enterprise 2.5" NVMe drives (U.2/U.3) and they will slot right into the R760’s bays. The server’s backplane and RAID/HBA controllers will auto-detect the drive type. No adapters needed – just ensure the drive is a 2.5" NVMe with U.2/U.3 interface.



  • 🔹 NVMe and Mixed Drive Support: Because of the universal backplane, you can mix NVMe and SAS/SATA drives in the R760 (though typically not in the same RAID array). The configurations Dell provides (8, 16, 24 bay) can be all-NVMe or a mix, but if you plan an NVMe SSD upgrade, verify that your backplane and controller support NVMe. (An R760 ordered with only SAS drives might have a backplane or RAID card that isn’t wired for NVMe in all slots.) It’s wise to check your system’s configuration or documentation to ensure NVMe capability on the bays you intend to use.​


Note: Dell’s documentation indicates the PowerEdge R760 even supports next-generation EDSFF drives (like E3.S form factor NVMe SSDs) up to 16 slots​. However, those are PCIe Gen5 devices and a special configuration. In this article, we’ll stick to the more common Gen4 NVMe 2.5" drives and their support in the R760.



NVMe SSD Form Factors and Boot Drive Options in the Dell PowerEdge R760


When upgrading the R760 with NVMe SSDs, it’s important to consider the form factor of the drives and how they will be used in the server. Here are the relevant form factors and options:


  • 🔸 2.5-inch U.2/U.3 NVMe Drives: These are the standard hot-swap NVMe SSDs that fit into the front (or rear) drive bays of the R760. They resemble traditional 2.5-inch drives but use a PCIe interface. The drives we’ll discuss (Samsung PM9A3, Kioxia CD6, etc.) all come in this form factor. Whether a drive is labeled U.2 or U.3, it will physically fit the R760’s combo backplane. These drives usually have a carrier/tray when purchased for Dell servers – ensure you have the correct Dell drive caddy so it slides into the R760’s bay properly. The server will typically show NVMe drive status via front LEDs and allow hot-plug replacement of these drives.



  • 🔸 NVMe M.2 (BOSS Card): For boot or OS drives, Dell offers a BOSS-N1 (Boot Optimized Storage Solution) module in the R760​. This is essentially a RAID controller card that holds two M.2 NVMe SSDs (usually M.2 2280 form factor) configured as a mirrored pair (RAID1) for reliability. The BOSS card is useful to dedicate boot drives (for ESXi, Linux OS, etc.) separate from the main hot-swap bays. Compatibility: The R760’s BOSS-N1 supports NVMe M.2 drives (previous generation BOSS cards were SATA). If you plan to use NVMe for your operating system, consider installing this module. It offloads the OS from the front bays and provides redundancy (if one M.2 fails, the other continues to boot the server). Common capacities for these M.2 boot drives are 240GB, 480GB, etc., which is plenty for an OS mirror.



  • 🔸 Add-in PCIe NVMe Cards: In some cases, NVMe upgrades might involve PCIe card-based SSDs (like NVMe drives on a PCIe card, or even GPU-like form factor). The R760 has up to 8 PCIe slots​, so one could use an adapter to mount an NVMe drive in a slot (for example, an AIC NVMe like Intel Optane or other specialized drives). However, for most standard storage upgrades, you’ll be using the dedicated drive bays rather than occupying PCIe slots with storage. It’s good to know the option exists if needed (e.g., if you wanted to add an NVMe that doesn’t fit the 2.5" bay form factor).



  • 🔸 Form Factor Considerations: Ensure any NVMe SSD you purchase for upgrade matches a supported form factor:

    • Front/Rear Bays: Use 2.5" U.2/U.3 NVMe drives in Dell-compatible caddies.

    • Boot: Use M.2 NVMe 2280 drives only on the BOSS card (the R760 doesn’t have native M.2 slots on the motherboard for storage).

    • Avoid EDSFF or others unless you specifically have the Dell kit for that (which is uncommon). Also avoid NVMe U.2 drives taller than 15mm, as the R760 drive bays typically fit 7mm or 15mm height 2.5" drives. Most enterprise NVMe are 15mm, which is fine.



  • 🔸 Hot Swap and Power Loss Protection: Enterprise NVMe SSDs used in servers like the R760 usually include power-loss protection capacitors and are hot-swappable. This means you can replace a failed NVMe drive while the system is running (assuming your OS/hardware configuration supports hot-plug). Always consult Dell’s docs for the proper procedure, but one advantage of NVMe in a server is no shut down needed for drive swaps – crucial for uptime.



Popular PCIe Gen4 NVMe SSDs for Dell PowerEdge R760


When selecting NVMe SSDs for a Dell PowerEdge R760 NVMe upgrade, you’ll want to use enterprise-grade drives that deliver high performance and reliability. Here are some popular Gen4 NVMe drives for servers (including models often used or certified by Dell) that would be excellent choices:


  • ⚙️ Samsung PM9A3: A mainstream enterprise NVMe SSD (PCIe 4.0) from Samsung. The PM9A3 offers a range of capacities (from ~1.92TB up to 7.68TB), using TLC NAND with strong performance and endurance for read-intensive workloads. It’s known for excellent sequential speeds (up to ~6.5 GB/s read) and high random IOPS. Samsung drives like the PM9A3 also feature power-loss protection and firmware optimized for consistent latency. In a PowerEdge R760, a Samsung PM9A3 can provide reliable high-speed storage for databases, virtualization, or caching. (Dell often rebrands Samsung enterprise SSDs under their own part numbers, so you might find a Dell PM9A3 variant as an upgrade option.)



  • ⚙️ Kioxia CD6: Kioxia (formerly Toshiba Memory) offers the CD6 Series NVMe SSD as an enterprise drive focused on read-intensive and mixed workloads. The CD6 is a PCIe 4.0 drive available in capacities up to around 7.68TB. It comes in U.3 2.5" form factor and includes features like end-to-end data protection and power-loss protection. The Dell R760 NVMe compatibility with Kioxia drives is solid, as Kioxia SSDs are used by many server OEMs. The CD6 delivers high reliability and a good balance of performance for general server applications (like VMs, SQL databases, etc.). It’s a great choice if you’re looking beyond Samsung and want to diversify your NVMe vendors.



  • ⚙️ Intel/ Solidigm P5510: The Intel P5510 (now under Solidigm since Intel’s SSD division was spun off) is another popular Gen4 NVMe SSD for enterprise use. It’s optimized for read-intensive scenarios and is offered in capacities from 3.84TB to 7.68TB (Intel also had smaller like 1.92TB). The P5510 uses TLC NAND and has a strong reputation for low latency and high throughput. In a PowerEdge R760, the P5510 can shine for workloads like analytics, content streaming, or as a high-speed storage pool for hypervisors. It also has firmware variants specifically validated for certain servers. If you have existing Intel drives (like P4510 Gen3 or similar), the P5510 is the Gen4 successor with roughly double the throughput. Note: Solidigm (Intel) drives are often found in Dell servers as well, sometimes labeled as “Dell D7-P5510” in documentation.



  • ⚙️ Micron 7400 PRO: Micron’s 7400 series is a PCIe 4.0 NVMe lineup that comes in various form factors (U.3 2.5", as well as M.2 and even E1.S). The 7400 PRO is geared toward read-intensive and general-purpose workloads, while the 7400 MAX variant covers higher endurance needs. For an R760, the Micron 7400 PRO in U.3 2.5" form is a compelling choice: it offers capacities from around 960GB up to 7.68TB, solid performance (~6.6 GB/s read, ~1M+ IOPS), and strong security features (like TCG encryption options). Micron drives are known for reliability and tend to be cost-effective. If you need a mix of drives, you might use 7400 PRO for most uses and maybe a couple of 7400 MAX for write-heavy logging or cache if needed – both would be compatible with the R760’s NVMe bays.


These four examples (Samsung, Kioxia, Intel/Solidigm, Micron) are well-regarded Gen4 NVMe SSDs that work in the PowerEdge R760. All of them have enterprise features such as: power loss protection (to avoid data corruption on sudden power loss), end-to-end data path protection, and robust endurance ratings. Importantly, they are NVMe 1.4 (or newer) and PCIe 4.0 x4 drives, which aligns perfectly with the R760’s capabilities.


Compatibility Tip: When possible, use Dell-certified versions of these drives (purchased through Dell or a reputable server parts supplier). Dell often provides firmware optimized for their servers, and the drive trays will fit without issue. The R760 will generally accept standard OEM NVMe drives too (it is quite flexible), but using Dell-specific part numbers can ensure you don’t run into any unexpected firmware or interoperability warnings. For example, Dell might list a “3.84TB RI NVMe SSD” in their config which internally is a Samsung PM9A3 or Kioxia CD6 with Dell firmware. If you acquire drives from server-parts specialists, you can request ones known to work in Dell systems.



Benefits of Upgrading to NVMe SSDs in the Dell PowerEdge R760


Upgrading a PowerEdge R760 from traditional SATA/SAS drives to NVMe SSDs yields significant performance and efficiency benefits. NVMe (Non-Volatile Memory Express) is a protocol designed specifically for flash storage, and when combined with PCIe Gen4 bandwidth in the R760, it can transform your server’s capabilities:


  • 🚀 Dramatically Lower Latency: NVMe drives communicate directly with the CPU over PCIe, eliminating the intermediate controllers (like SAS HBAs or SATA controllers). This direct path means much lower latency for each IO operation. An NVMe SSD in the R760 can have latency on the order of 100 microseconds or less, whereas even the fastest SAS/SATA SSDs might be 2-3x higher. For databases and transaction-heavy applications, this reduction in latency translates to snappier responses and the ability to handle more operations per second.



  • 🚀 Higher IOPS and Throughput: A single NVMe Gen4 SSD can easily deliver hundreds of thousands of IOPS (input/output operations per second). In contrast, a single SATA SSD might offer tens of thousands of IOPS. For example, an NVMe like the Intel P5510 can reach ~900K random read IOPS in optimal conditions. If you populate multiple NVMe drives in the R760, the aggregate IOPS scales up tremendously, enabling you to run IO-intensive workloads (like virtualization with lots of VMs, or large web databases) without storage becoming the bottleneck. Throughput is also vastly improved: PCIe 4.0 NVMe drives can each provide up to 7-8 GB/s of sequential read throughput. So, upgrading to NVMe can accelerate large file transfers, backups, and data streaming applications dramatically.



  • 🚀 Better Parallelism (Ideal for Multi-Core CPUs): NVMe is built for parallel operation with deep queues (it supports many concurrent command queues and commands per queue). This means an NVMe storage system can fully utilize the multiple CPU cores in a dual-socket R760 when handling IO. With SAS/SATA, a single queue often becomes a chokepoint under heavy load. NVMe drives in an R760 allow each core to fetch and store data concurrently without waiting in line, which maximizes CPU utilization for data-intensive tasks.



  • 🚀 Reduced Footprint and Power (vs Spinning Disks): If you’re upgrading from HDDs or even from older SATA SSDs, NVMe can offer a better IOPS-per-Watt ratio and far higher density. One NVMe drive can replace dozens of hard disks in performance. By consolidating to NVMe, you free up drive bays and reduce the complexity of RAID groups needed to achieve performance. This can simplify storage management and potentially reduce power and cooling costs (though note that NVMe SSDs do consume more power per drive than SATA SSDs, their vastly higher performance usually means you need fewer drives for the same or greater output).



  • 🚀 Enhanced Reliability for Critical Workloads: Enterprise NVMe SSDs are designed with reliability features such as power-loss protection capacitors, advanced wear leveling, and telemetry for drive health. Upgrading to NVMe in a PowerEdge means you’re leveraging these enterprise features. Also, by using mirrored boot drives (via BOSS card) and possibly RAID for data volumes (via NVMe RAID or software RAID), you can achieve high availability even with super-fast storage. In scenarios like high-frequency trading, real-time analytics, or VDI, the combination of R760 + NVMe ensures both speed and reliability.


In summary, moving to NVMe SSDs can reduce storage latency, boost IOPS and throughput, and improve the overall application performance on your Dell R760. Users often experience faster boot times, quicker database queries, and an ability to handle more workload on the same server once NVMe drives are in place.



Tips for Selecting the Right Gen4 NVMe Drives for Your Dell PowerEdge R760


Not all NVMe drives are created equal. When planning an enterprise NVMe SSD upgrade for your R760, consider the following tips to choose the most suitable drives:


  • 💡 Match Drive Endurance to Workload: Enterprise SSDs come with different endurance ratings, typically measured in DWPD (Drive Writes Per Day) over a 5-year span. For example, a drive might be rated for 1 DWPD (good for read-heavy or general use) or 3 DWPD (for write-intensive use like caching or logging). Assess your workload – if your R760 will run databases or high-write applications, opt for higher endurance models (often labeled “Mixed Use” or “Write Intensive”). For lighter reads or boot/system drives, “Read Intensive” 1 DWPD models (which usually also have higher capacity per $$) are sufficient. All the drives mentioned (PM9A3, CD6, P5510, 7400) have endurance classes; they often come in variants, so pick the variant that meets your needs. It’s better to have some endurance headroom to avoid premature wear-out.



  • 💡 Ensure Firmware and Controller Compatibility: The R760 will work with standard NVMe drives, but using drives with Dell firmware can ensure full compatibility with Dell’s controllers and management software (iDRAC). If you use non-Dell OEM drives, make sure:

    • The drive’s firmware is up-to-date (to the latest from the manufacturer).

    • The drive supports NVMe standards that Dell uses (most NVMe 1.3+ drives do).

    • You might see a warning in iDRAC for “non-Dell drive” but functionality should be fine. If that’s a concern, source Dell-branded versions.Additionally, if you plan to use Dell’s hardware RAID (PERC) with NVMe, stick to Dell-supported drives to avoid any firmware-level incompatibility with the RAID controller. For example, the PERC 12 RAID controller in the R760 has a compatibility matrix of drives it will allow for RAID. Drives used in HBA (pass-through) mode are less restrictive.



  • 💡 Thermal Considerations: NVMe SSDs, especially Gen4 models, can run hot under sustained load. The PowerEdge R760 is built for good airflow (Dell’s “Smart Flow” chassis), but you should still ensure:

    • All drive bay blanks are in place for bays that are empty (to maintain proper airflow over the populated drives).

    • Use enterprise drives that have heat spreaders or enclosures designed for servers. (All the listed drives do).

    • Monitor drive temperatures via iDRAC or software. If you see very high temps, the R760 has options for high-performance fans. In extreme cases (all 24 bays filled with high-power NVMe), consider the high-performance fan configuration to keep temperatures in check.



  • 💡 Power and Cooling Headroom: Each NVMe drive may consume anywhere from 8W on the low end to 20-25W on high end (especially at peak load). If you are populating many drives, ensure your server’s power supplies can handle the added load. For instance, if you originally had only a few SATA drives (very low power) and you’re adding 16 NVMe, that could add ~150W or more of consumption under load. Dell’s sizing tools can help, or consult with a server power calculator. In terms of cooling, as mentioned, have adequate cooling (standard fan config usually suffices up to a point).



  • 💡 Capacity vs Performance Balance: Larger capacity NVMe drives often have slightly better performance (more NAND chips to parallelize) but also higher cost. Sometimes using fewer large drives is more efficient than many small ones, but consider your capacity needs and redundancy. For example, 8 x 3.84TB NVMe might be a sweet spot for both capacity and performance in an R760. But if you need maximum capacity, 15.36TB drives exist (though at higher cost per drive). Also plan for RAID or redundancy: if using software RAID-1 or RAID-5/6 with NVMe, factor in needing extra drives for parity/mirroring.



  • 💡 Enterprise Features to Look For: Make sure the NVMe SSDs have features like PLP (Power Loss Protection) – all the ones listed do, but if you consider other models, double-check. Also look at the warranty and support. Enterprise drives usually have 5-year warranties. If buying from a reseller, ensure they can support any issues or have a return policy in case a drive doesn’t play nice with your R760. It’s also wise to standardize on one or two models of NVMe in the server rather than many different models, for consistency in management and performance.



  • 💡 Check Dell Support Resources: Dell often updates BIOS and backplane firmware to improve NVMe support. Before installing new drives, it’s a good practice to update your R760’s BIOS, backplane firmware, and drive firmware (if using Dell drives, use their firmware packages). This can resolve known issues and ensure optimal compatibility. The Dell Support site and forums can have notes on which SSD models are validated for the R760 – a quick check can give you peace of mind that your chosen NVMe is known to work well.


By carefully selecting NVMe SSDs with the right endurance, firmware, and thermal profile, you’ll set your R760 up for a successful upgrade. If in doubt, consulting with a specialist or the server manufacturer (or a partner like server-parts.eu) can help identify the best drive model for your needs.



Best Practices for Installing and Configuring NVMe SSDs in Dell PowerEdge R760


Upgrading to NVMe SSDs in a server is not difficult, but there are best practices to follow for a smooth installation and optimal performance. Here’s a checklist of steps and considerations when adding NVMe drives to your Dell PowerEdge R760:


Plan Downtime or Hot-Swap Appropriately: If you are adding NVMe drives to empty slots, you may do so online (the R760 supports hot-plug for NVMe). However, if you are replacing existing drives or don’t have hot-swap enabled, schedule a maintenance window. Always ensure you have current backups of any critical data before making hardware changes.



Wear ESD Protection & Handle Carefully: NVMe drives are static-sensitive. Wear an anti-static wrist strap and handle the drives by the sides. Avoid touching the connector or components. The R760 drive trays will securely hold the drives – screw the NVMe SSD into the tray if it’s not pre-mounted. Make sure it’s snug and the connector is correctly aligned with the backplane interface.



Update Firmware and BIOS: Before or immediately after installation, update your server’s BIOS, iDRAC, and backplane (BP) firmware to the latest version from Dell. These updates often include improvements for NVMe drive support and stability. If your NVMe drives are Dell-branded, update their firmware via Dell’s repository if a newer version is available. Up-to-date firmware helps prevent issues like drives dropping offline or performance quirks.



Configure BIOS Settings: Enter the R760 BIOS/UEFI settings and ensure the NVMe settings are configured as needed. Typically, for NVMe there isn’t much to change except:


Boot Settings: If you plan to boot from an NVMe drive (not using BOSS), make sure UEFI boot mode is enabled (NVMe drives require UEFI to boot, legacy BIOS won’t see them as bootable). Add the NVMe drive to boot order if an OS is installed on it.

RAID Settings: If using a hardware RAID controller for NVMe (like PERC H755N or H965i NVMe RAID), you might need to enable/disable RAID mode in BIOS or through the controller’s setup. If you’re not using hardware RAID (just individual drives or software RAID), ensure the controller is in HBA/Pass-through mode for NVMe so the OS can see each drive directly.

Security: If you plan to use NVMe self-encryption (SED) features, configure the BIOS to enable PCIe Slot security or NVMe drive security features accordingly.



Use the Correct Drive Slots: Consult the R760 manual to identify which slots are NVMe-capable if you have a mixed backplane. Typically, all slots in a U.3 backplane are NVMe-capable, but sometimes only certain slots get PCIe lanes with one CPU populated. For example, in a dual-socket server, half the NVMe bays might be wired to CPU1 and the other half to CPU2. If you only have one CPU installed, note that some NVMe bays may not work until the second CPU is added (their lanes terminate at the missing CPU). So plan drive placement accordingly or install a second CPU if you need all NVMe lanes active.



Operating System Configuration: Modern operating systems (Windows Server 2019/2022, most Linux distributions, VMware ESXi, etc.) have built-in NVMe drivers. After installing the drives:

Verify the OS recognizes the NVMe SSDs. On Linux, lspci and lsblk should show NVMe devices. On Windows, check Device Manager and Disk Management. In ESXi, check storage adapters for NVMe controllers.

If you added drives to an existing Linux system, you may need to rescan the PCIe bus (e.g., echo 1 > /sys/bus/pci/rescan). In Windows, use Device Manager’s “Scan for hardware changes.”



Filesystem and Alignment: When creating partitions on NVMe, the OS usually aligns partitions correctly by default (2048-sector offset). It’s generally not an issue nowadays, but just use modern tools to partition/format. For best performance on NVMe, use appropriate filesystems (e.g., NTFS/ReFS on Windows, ext4/XFS on Linux, VMFS on ESXi) and enable features like TRIM/discard if supported to help the SSD maintain performance.



RAID or Not to RAID: Decide whether to use RAID for your NVMe drives:

Hardware RAID: The R760 supports the PERC 12 series controllers that can do NVMe RAID (H965i, etc.). If you have those installed and want a RAID5/6 or RAID10 across NVMe drives for data protection, enter the RAID controller configuration (Ctrl-R or via Dell OpenManage) and create your virtual disk from the new NVMe drives. Keep in mind hardware RAID on NVMe is much improved with PERC 12, offering high performance​, but it still adds a layer that might not be necessary if you can do software mirroring or if your application handles redundancy.

Software RAID: Many prefer to use software RAID (Storage Spaces in Windows, mdraid/ZFS in Linux) with NVMe to avoid additional latency. The R760’s powerful CPUs can handle software RAID easily given NVMe’s low overhead. If you go this route, after OS detects the drives, create your software RAID volume as you normally would.


No RAID: If using the drives individually (each for a separate purpose or part of a distributed system), just ensure each drive is properly labeled and monitored.



Monitoring and Testing: Once installed, keep an eye on the new NVMe drives:

Use Dell iDRAC or OpenManage to check drive health status, temperature, and any logged events. Non-Dell firmware drives might not show full info, but basics (temp, SMART status) should be visible.

Run some benchmark or stress test appropriate for your environment (e.g., fio on Linux, DiskSpd on Windows, or even simple copy tests) to ensure the drives are performing as expected and stable under load.

Monitor for any firmware messages or NVMe warnings in the system log. It’s easier to address issues early rather than after putting them in production use.



Maintain Spares and Backup: With any RAID or critical storage, maintain at least one spare NVMe drive on hand if possible. NVMe drives are very reliable, but in high duty-cycle environments they can fail eventually. Having a cold spare ready can reduce replacement time. Also, continue regular data backups – fast storage still needs a solid backup strategy!


By following these best practices, you can confidently install and configure NVMe SSDs in your Dell R760, ensuring you get the maximum benefit with minimal hassle. The key is preparation – verifying hardware support, updating firmware, and planning the config – after that, the performance gains will be well worth the effort.



Common Mistakes to Avoid During NVMe SSD Upgrades in Dell PowerEdge R760


Upgrading to NVMe on the R760 is straightforward, but there are some common mistakes or pitfalls that administrators should avoid. Here are some to watch out for, so you can ensure a smooth upgrade without unpleasant surprises:


  • ⚠️ Assuming Any NVMe Drive Will Work: Not all NVMe SSDs are suitable for server use. Avoid using consumer-grade NVMe drives (like a Samsung 970/980 PRO, etc.) in the R760. Even though they fit physically via adapters, consumer drives lack power loss protection, have lower endurance, and firmware not validated for server workloads. Always choose enterprise NVMe models for the R760. Also, double-check that the drive’s form factor is correct (e.g., some newer NVMe might come in odd form factors like U.2 15mm—fine, but others might be E1.S or thicker drives that won’t fit).



  • ⚠️ Not Verifying Backplane/Controller Support: As mentioned, your R760 needs the right backplane to support NVMe. A common mistake is buying a server that has a SAS/SATA-only backplane and then trying to insert NVMe drives – those drives won’t be recognized. If your configuration was for HDDs originally (say, 12 x 3.5” chassis), and you attempt to put NVMe U.2 drives with adapters, it likely won’t work because the lanes and connectors aren’t in place. Solution: Check your Service Tag config or manual to ensure NVMe support, or purchase an NVMe-capable backplane and cables to retrofit (which can be an involved process). It’s easiest to order the server with NVMe support from the start, but upgrades are possible with the right parts.



  • ⚠️ Mixing Drive Types Without Planning: While the R760 can mix NVMe and SATA drives electrically, mixing them within the same workload or RAID can bottleneck the NVMe. For example, putting NVMe and SATA in one RAID array will make the whole array perform at SATA speeds. Similarly, using an NVMe and expecting it to mirror to a slower SATA drive (via software RAID) will be limited by the slower drive. Avoid mixing unless each drive type is assigned to different tasks. If you need a tiered setup (hot data on NVMe, cold on SATA), use proper tiering software or manage it at application level.



  • ⚠️ Ignoring CPU/Lane Affinity: As noted, in a dual-socket server like the R760, NVMe bays are typically split between the two CPUs. A mistake is populating all NVMe drives but only one CPU is installed – half the drives won’t show up because the second CPU (and its PCIe lanes) are missing. The R760 with a single CPU might only support some of the front bays (e.g., bays 0-7) for NVMe. Check the documentation for which bays are tied to CPU1 vs CPU2. If you only have one CPU and need all those NVMe drives accessible, you’ll likely need to add the second CPU to get the full complement of PCIe lanes active.



  • ⚠️ Not Cooling Adequately: Filling a server with NVMe drives and not monitoring the thermals is a mistake. NVMe drives throttling due to high temperature will severely hurt performance (in some cases, a drive might drop to a fraction of its speed if overheated). Ensure the server’s fans are set to auto/high performance as needed. Also, don’t leave empty slots open – use blank fillers to direct airflow correctly. If drives are running hot, consider using higher-performance fan options or reducing ambient temperature. Regularly clean filters or ensure the data center airflow is good, as dense NVMe configurations push the thermal envelope.



  • ⚠️ Forgetting to Update Drive Firmware: Enterprise SSDs get firmware updates too. A common oversight is to install drives and never check for firmware updates, which could fix bugs (like corner-case crashes or performance issues). Dell drives can be updated through Dell tools; retail drives might have firmware tools from the manufacturer. Schedule periodic checks (perhaps during planned maintenance windows) for firmware updates on your NVMe SSDs and apply them if beneficial.



  • ⚠️ Improper Drive Replacement Procedures: If an NVMe drive fails and you need to replace it, remember that NVMe hot swap requires coordination with the OS:

    • In Windows, use Optimize Drive Removal if available or ensure the drive isn’t in use, then pull it. In Linux, you might need to use nvme detach or similar to safely remove an NVMe device, or ensure no I/O is happening and unmount it.

    • Failing to do so can sometimes hang the bus or cause a glitch. It’s not as common as with external devices, but best practice is to inform the OS.

    • When inserting a new drive, ensure it’s recognized (rescan the NVMe controller if needed).

    • If using a RAID controller, offline the failed drive in the RAID utility before removal if it didn’t already recognize the failure.



  • ⚠️ Treating NVMe Just Like Old Storage in All Scenarios: NVMe unlocks new possibilities (like direct CPU access, NVMe-oF, etc.). A mistake would be not considering how to optimize your software stack to fully utilize NVMe. For example, with ultra-fast storage, you might need to adjust queue depths, or concurrency in your database, or enable features like multi-queue I/O in your OS to get the best performance. If you simply swap from HDDs to NVMe but keep old tuning parameters, you might not see full gains. This is more of a tuning consideration than a “mistake,” but it’s worth mentioning: revisit your storage-related software settings post-upgrade.


Avoiding these pitfalls will help ensure your NVMe SSD upgrade goes smoothly. When in doubt, consult Dell’s official documentation or reach out to experienced professionals. It’s easier to double-check beforehand than to troubleshoot later.



Dell PowerEdge R760 NVMe SSDs - Save Up to 80%

✔️ No Upfront Payment Required - Test First, Pay Later!


Opmerkingen